Repository logo
Institutional Digital Repository
Shreenivas Deshpande Library, IIT (BHU), Varanasi

A mathematical model to predict the different isodose volumes using TRAK value in HDR intracavitary brachytherapy for revised Manchester and ICRU-89 based Point A plans using computer tomography images

dc.contributor.authorMourya, Ankur
dc.contributor.authorChoudhary, Sunil
dc.contributor.authorSharma, Neeraj
dc.contributor.authorShahi, Uday Pratap
dc.contributor.authorSingh, Gaganpreet
dc.contributor.authorPradhan, Satyajit
dc.contributor.authorAggarwal, Lalit Mohan
dc.date.accessioned2023-04-20T07:30:22Z
dc.date.available2023-04-20T07:30:22Z
dc.date.issued2022-07
dc.descriptionThis paper is submitted by the author of IIT (BHU), Varanasi, Indiaen_US
dc.description.abstractTo find out the simple relationship between Total Reference Air Kerma (TRAK) and various isodose volumes. Calculated isodose volumes were compared with experimental data for revised Manchester and International Commission on Radiation Units and measurements (ICRU)-89 Point A-based treatment plans. The accuracy of the formula was compared with the results of other relationships available in the literature. Materials and Methods: Dosimetric data from 62 intracavitary brachytherapy (ICBT) treatment plans of 31 patients with cervical cancer were studied. Each patient had treatment plans normalized to revised Manchester and ICRU-89 Points A (A flange and A icru89). For each treatment plan, TRAK values, V 350, V 700, V 1050, and V 1400 were obtained. The modeling curve was plotted between Isodose volume (V d) and the ratio of d/TRAK obtained from A flange plans to get a mathematical relation. The results of this formula were compared with the experimental data and outcomes of other formulas available in the literature. A paired-sample t-Test was performed to assess the statistical significance. Results: In the case of revised Manchester-based A flange normalization plans, the mean isodose volume of V 350, V 700, V 1050, and V 1400 were 285.98 ± 32.3 cm 3, 101.96 ± 10.63 cm 3, 52.71 ± 4.72 cm 3, and 31.44 ± 2.33 cm 3 respectively. Likewise, for ICRU-89 based A icru89 normalization plans, the mean isodose volumes of V 350, V 700, V 1050, and V 1400 were 304.11 ± 26.17 cm 3, 108.88 ± 8.29 cm 3, 56.62 ± 3.69 cm 3 and 34 ± 2.23 cm 3 respectively. The mean difference was significant. The Mathematical relationship developed was [INLINE:1]. No correlation was found between TRAK and D 0.1cm 3,D 2cm 3 for organs at risk. Conclusions: The developed formula calculated isodose volumes within the accuracy of ± 3% in ICBT plans.en_US
dc.identifier.issn09731482
dc.identifier.urihttps://idr-sdlib.iitbhu.ac.in/handle/123456789/2135
dc.language.isoenen_US
dc.publisherWolters Kluwer Medknow Publicationsen_US
dc.relation.ispartofseriesJournal of Cancer Research and Therapeutics;Volume 18, Issue 4, Pages 1105 - 1113
dc.subjectAmerican Brachytherapy Societyen_US
dc.subjectCervical brachytherapyen_US
dc.subjectICRUen_US
dc.subjectIntracavitary brachytherapyen_US
dc.subjectIsodoseen_US
dc.subjectTotal reference air kermaen_US
dc.subjectBrachytherapyen_US
dc.subjectComputersen_US
dc.subjectFemaleen_US
dc.subjectHumansen_US
dc.subjectModelsen_US
dc.subjectTheoreticalen_US
dc.subjectRadiotherapy Dosageen_US
dc.subjectRadiotherapy Planningen_US
dc.subjectComputer-Assisteden_US
dc.subjectRectumen_US
dc.subjectTomographyen_US
dc.subjectX-Ray Computeden_US
dc.subjectUterine Cervical Neoplasmsen_US
dc.subjectadult; Article; brachytherapy; cancer patient; clinical article; computer assisted tomography; controlled study; female; human; mathematical model; treatment planning; uterine cervix cancer; volume; computer; diagnostic imaging; procedures; radiotherapy dosage; radiotherapy planning system; rectum; theoretical model; uterine cervix tumor; x-ray computed tomographyen_US
dc.titleA mathematical model to predict the different isodose volumes using TRAK value in HDR intracavitary brachytherapy for revised Manchester and ICRU-89 based Point A plans using computer tomography imagesen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
A_mathematical_model_to_predict_the_different.35.pdf
Size:
1.85 MB
Format:
Adobe Portable Document Format
Description:
Article - Bronze Open Access

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: