Repository logo
Institutional Digital Repository
Shreenivas Deshpande Library, IIT (BHU), Varanasi

Mass and Momentum Transfer to Newtonian and Non-Newtonian Fluids in Fixed and FluSdized Beds

dc.contributor.authorKumar S.; Upadhyay S.N.
dc.date.accessioned2025-05-24T09:56:26Z
dc.description.abstractMass transfer and pressure drop measurements during flow of Newtonian and non-Newtonian fluids through fixed and fluidized beds of uniformly sized cylindrical pellets and spheres have been made. Demineralized water and 1.0% aqueous carboxymethyl cellulose (CMC) solution have been used as the fluids. Measurements have covered a particle Reynolds number range from 0.0387 to 6000 and Schmidt numbers from 816 to 71871. It has been shown that with appropriate choice of a viscosity, the results for both Newtonian and non-Newtonian fluids can be expressed by correlations based on the capillary tube bundle model. © 1981, American Chemical Society. All rights reserved.
dc.identifier.doihttps://doi.org/10.1021/i100003a002
dc.identifier.urihttp://172.23.0.11:4000/handle/123456789/20992
dc.relation.ispartofseriesIndustrial and Engineering Chemistry Fundamentals
dc.titleMass and Momentum Transfer to Newtonian and Non-Newtonian Fluids in Fixed and FluSdized Beds

Files