Repository logo
Institutional Digital Repository
Shreenivas Deshpande Library, IIT (BHU), Varanasi

Electrochemical corrosion behavior of tantalum coated 316L stainless steel by D.C. Magnetron sputtering for orthopedic applications

dc.contributor.authorPathote, Dileep
dc.contributor.authorJaiswal, Dheeraj
dc.contributor.authorSingh, Vikrant
dc.contributor.authorBehera, C.K.
dc.date.accessioned2024-02-28T09:38:39Z
dc.date.available2024-02-28T09:38:39Z
dc.date.issued2022-12-28
dc.descriptionThis paper published with affiliation IIT (BHU), Varanasi in open access mode.en_US
dc.description.abstractThe austenitic stainless steel type 316L was engineered with a thin multilayer of tantalum with a thickness of 1.504µm, 3.893 µm and 6.083µm and a duration of 15, 30 and 60 minutes, respectively, by the DC Magnetron Sputtering. Electrochemical behaviors of all three samples were investigated by potentiodynamic and electrochemical impedance spectroscopy techniques. Simulated body fluid was used as the corrosive medium for the electrochemical measurement. The highest corrosion resistance was obtained for the sample subjected to 60 minutes of Ta deposited on 316L S.S. according to EIS measurements, and the lowest corrosion rate of 0.0047 mm/year was obtained for the same sample according to the PD measurements. All the measurements were carried out after the determination of open circuit potential (OCP) at 37˚C with 1 ±°C. All the samples were then characterized by scanning electron microscopy (SEM) to observe the morphology of coating after corrosion. The number of corrosion pits observed from the SEM micrograph was much less on the three coated samples compared to the bare sample. X-ray Photoelectron Spectroscopy (XPS) was used to identify the chemical states of coated and bare 316L SS. Ta4f is present as oxidation states in Ta coated stainless steel 316L, whereas Ta4f is the main species examined along with other elements (C1s, N1s, O1s, Cr2p, Fe2p, Ni2p, and Mo3d). It was also observed that there was strong adhesion between substrate and Ta-coating. After the potentiodynamic studies, results show a significant improvement in corrosion resistance attributed to the strong, stable oxide layer formation.en_US
dc.description.sponsorshipThe authors gratefully acknowledge the funding from the Science and Engineering Research Board (SERB) of India ( Project No. R&D/SERB/MET/19-20/04 ), and for the research experimental facilities of the ‘’Indian Institute of Technology Banaras Hindu University’’ (IIT-BHU), Varanasi-221005 India.en_US
dc.identifier.issn26665239
dc.identifier.urihttps://idr-sdlib.iitbhu.ac.in/handle/123456789/2976
dc.language.isoenen_US
dc.publisherElsevier B.V.en_US
dc.relation.ispartofseriesApplied Surface Science Advances;13
dc.subject316L stainless steelen_US
dc.subjectCorrosionen_US
dc.subjectOrthopedic applicationsen_US
dc.subjectTantalum coatingen_US
dc.titleElectrochemical corrosion behavior of tantalum coated 316L stainless steel by D.C. Magnetron sputtering for orthopedic applicationsen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Electrochemical corrosion behavior of tantalum coated 316L stainless steel by D.C. Magnetron sputtering for orthopedic applications.pdf
Size:
14.12 MB
Format:
Adobe Portable Document Format
Description:
Electrochemical corrosion behavior of tantalum coated 316L stainless steel by D.C. Magnetron sputtering for orthopedic applications

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: