dc.description.abstractLiquid storage tanks are used to store oil, drinking water and different liquids which are necessary in industry and energy production. Partially liquid filled container shows free surface movement under external excitation this phenomenon is known as sloshing of liquid. When external excitation frequency matches the natural frequency of sloshing, a violent oscillation may occur that causes excess dynamic pressure on the tank structure. The dynamic behavior of liquid storage tanks under seismic excitation has been the subject of numerous theoretical and experimental investigations. This paper presents a pressure based finite element analysis of the liquid-structure systems considering the coupled effect of elastic structure and liquid. The equation of motion of the liquid is considered as incompressible and inviscid. The hydrodynamic pressure variation along a wall of prismatic container is studied and presented for different fill depth of liquid under sinusoidal base excitation. © 2011 American Institute of Physics.