Evaluation of surface-modified orthodontic wires by different concentration and dipping duration of titanium oxide (TiO 2) nanoparticles

dc.contributor.authorChaturvedi T.P.
dc.contributor.authorIndumathi P.
dc.contributor.authorSharma, Vipul Kumar
dc.contributor.authorAgrawal, Ashish
dc.contributor.authorSingh, Deepak
dc.contributor.authorUpadhyay, Chandan
dc.date.accessioned2024-02-05T12:01:57Z
dc.date.available2024-02-05T12:01:57Z
dc.date.issued2023-03-18
dc.descriptionThis paper published with affiliation IIT (BHU), Varanasi in open access mode.en_US
dc.description.abstractOBJECTIVE: To evaluate in-vitro surface characteristics and frictional properties of orthodontic stainless steel and beta-titanium archwires after surface modification with different concentrations and coating time of titanium oxide (TiO 2) nanoparticles by Sol-gel dip coating method. MATERIALS AND METHODS: The experiment was carried out with 4 different concentrations (1:2, 1:4, 1:6, and 1:8) and three different dipping durations (24 hours, 48 hours, and 72 hours) over ten main test groups of SS and TMA archwires with uncoated wires acting as control in both dry and wet conditions. Phase analysis and surface characterization of TiO 2 was analyzed by X-ray Diffractometry, surface evaluation with the help of scanning electron microscopy (SEM), and frictional characteristics were evaluated. RESULTS: Among all the concentrations 1:6 ratio with 48 hours of dipping duration showed better surface characteristics. A statistically significant difference in frictional coefficient was observed in both SS and TMA wires than their respective controls (p = 0.001). Intragroup comparison among SS and TMA groups showed that groups with 1:6 ratio and 48 hours dipping duration had least frictional coefficient in both dry and wet conditions (p = 0.001). Intergroup comparison between SS and TMA showed that SS group had significantly reduced friction than TMA (p = 0.001) except in few groups. CONCLUSION: TiO 2 nanoparticle with a concentration ratio of 1:6 and 48 hours dipping duration is recommended for surface modification of orthodontic archwires.en_US
dc.identifier.issn22781897
dc.identifier.urihttp://localhost:8080/xmlui/handle/123456789/2825
dc.identifier.urihttps://idr-sdlib.iitbhu.ac.in/handle/123456789/2825
dc.language.isoenen_US
dc.publisherWolters Kluwer Medknow Publicationsen_US
dc.relation.ispartofseriesJournal of Orthodontic Science;12
dc.subjectCoatingen_US
dc.subjectfrictionen_US
dc.subjectnanoparticlesen_US
dc.subjectorthodontic wiresen_US
dc.subjectsurface modificationen_US
dc.titleEvaluation of surface-modified orthodontic wires by different concentration and dipping duration of titanium oxide (TiO 2) nanoparticlesen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
evaluation_of_surface_modified_orthodontic_wires.3.pdf
Size:
1.72 MB
Format:
Adobe Portable Document Format
Description:
Evaluation of surface-modified orthodontic wires by different concentration and dipping duration of titanium oxide (TiO 2) nanoparticles

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: