Recovery of the electrical insulation of a van de Graaff accelerator's charging belt by vacuum drying
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
The insulation of a moisture exposed “leaky” charging belt of AN-400 Van-de-Graaff Accelerator was successfully restored by vacuum drying. Although the drying time is of nearly one week, the technique is comparatively easy, risk free and superior to other alternative techniques and does not require dismantling of the belt. Copyright © 1986 by The Institute of Electrical and Electronics Engineers, Inc.