A Communication-assisted Scheme in Radial Distribution Systems Using Phasor Measurement Units

dc.contributor.authorJain, A.
dc.contributor.authorVerma, M.K.
dc.date.accessioned2021-01-21T09:40:41Z
dc.date.available2021-01-21T09:40:41Z
dc.date.issued2020-09
dc.description.abstractAutomation of the distribution system may be an essential requirement in the smart grid architecture. In this paper, the architecture of the distribution system has been proposed, where Phasor Measurement Unit (PMU) has been placed at the main substation receiving supply from the grid through the incoming feeder, as well as at all distribution transformers (DTs). PMU installed at the main substation is linked to master controller through IEC 61850. PMUs placed at DTs are connected to the corresponding local controller through the IEC 61850. Estimated voltage and current phasors together with frequency are transmitted from PMU to the local controller through IEC 61850 communication protocol. Controllers perform different tasks based on the data received from PMUs. Each local controller is linked to master controller as well as to all smart meters placed at loads supplied by the DT. Bidirectional exchange of information takes place between master and local controllers as well as between local controller and smart meter. PMUs are also linked with the smart meters using PLC communication link. In this paper, information about the available power at the substation and at the distribution transformer is developed in real-time with the help of PMU by considering the load disconnection/connection based on available power (from time t = 0.56sec to time t = 0.75sec), protection of feeder against overcurrent (from time t = 0.15sec to time t = 0.20sec), and power theft detection and elimination (from time t = 0.21sec to time t = 0.23sec) through eMEGASim® OP5600 OPAL-RT real-time simulator. © 2019 IETE.en_US
dc.identifier.issn02564602
dc.identifier.issn02564602
dc.identifier.urihttps://idr-sdlib.iitbhu.ac.in/handle/123456789/1275
dc.language.isoenen_US
dc.publisherTaylor and Francis Ltd.en_US
dc.relation.ispartofseriesIETE Technical Review (Institution of Electronics and Telecommunication Engineers, India);Vol. 37, Issue 5
dc.subjectAvailable power lossen_US
dc.subjectdistribution systemen_US
dc.subjectIEC 61850en_US
dc.subjectphasor measurement unit (PMU)en_US
dc.subjectprotocolen_US
dc.subjectsmart meteringen_US
dc.titleA Communication-assisted Scheme in Radial Distribution Systems Using Phasor Measurement Unitsen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
A-Communicationassisted-Scheme-in-Radial-Distribution-Systems-Using-Phasor-Measurement-Units2020IETE-Technical-Review-Institution-of-Electronics-and-Telecommunication-Engineers-IndiaOpen-Access.pdf
Size:
3.48 MB
Format:
Adobe Portable Document Format
Description:
Open Access

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: