Repository logo
Institutional Digital Repository
Shreenivas Deshpande Library, IIT (BHU), Varanasi

Au nanoparticles modified CuO nanowireelectrode based non-enzymatic glucose detection with improved linearity

dc.contributor.authorMishra, A.K
dc.contributor.authorJarwal, D.K
dc.contributor.authorMukherjee, B
dc.contributor.authorKumar, A
dc.contributor.authorRatan, S
dc.contributor.authorTripathy, M.R
dc.contributor.authorJit, S
dc.date.accessioned2020-10-13T11:19:57Z
dc.date.available2020-10-13T11:19:57Z
dc.date.issued2020-12-01
dc.descriptionOpen Access Reporten_US
dc.description.abstractThis paper explores gold nanoparticle (GNP) modified copper oxide nanowires(CuO NWs)based electrode grown on copper foil for non-enzymatic glucose detection in a wide linear ranging up to 31.06 mM, and 44.36 mM at 0.5 M NaOH and 1 M NaOH concentrations. The proposed electrode can be used to detect a very low glucose concentration of 0.3 µM with a high linearity range of 44.36mM and sensitivity of 1591.44 µA mM−1 cm−2. The electrode is fabricated by first synthesizing Cu (OH)2 NWs on a copper foil by chemical etching method and then heat treatment is performed to convert Cu (OH)2 NWs into CuO NWs. The GNPs are deposited on CuO NWs to enhance the effective surface-to-volume ratio of the electrode with improved catalytic activity. The surface morphology has been investigated by XRD, XPS, FE-SEM and HR-TEM analysis. The proposed sensor is expected to detect low-level of glucose in urine, and saliva. At the same time, it can also be used to measure extremely high sugar levels (i.e. hyperglycemia) of ~ 806.5454 mg/dl. The proposed sensor is also capable of detecting glucose after multiple bending of the GNP modified CuO NWs electrode. The proposed device is also used to detect the blood sugar level in human being and it is found that this sensor’s result is highly accurate and reliable.en_US
dc.identifier.issn2045-2322
dc.identifier.urihttps://idr-sdlib.iitbhu.ac.in/handle/123456789/801
dc.language.isoen_USen_US
dc.publisherNatureen_US
dc.relation.ispartofseriesScientific Reports;Vol 10, Issue 1
dc.subjectnanoparticlesen_US
dc.subjectnanowireelectrodeen_US
dc.subjectnon‑enzymatic glucoseen_US
dc.subjectglucoseen_US
dc.titleAu nanoparticles modified CuO nanowireelectrode based non-enzymatic glucose detection with improved linearityen_US
dc.typeTechnical Reporten_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Au-nanoparticles-modified-CuO-nanowireelectrode-based-nonenzymatic-glucose-detection-with-improved-linearity2020Scientific-ReportsOpen-Access.pdf
Size:
3.77 MB
Format:
Adobe Portable Document Format
Description:
Scientific report

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: