Study on the Self-Discharge of an All-Vanadium Redox Flow Battery through Monitoring Individual Cell Voltages
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Power generation from renewable energy sources along with energy storage systems for consistent power supplies might be a solution to attain net-zero carbon emissions. Recently, all-vanadium redox flow batteries (VRFBs) have gained popularity because of their long cycle life, ease of maintenance, and flexible power/capacity configurations. Understanding the process of cell response over time is deemed to be essential for settling the performance-limiting factors. The main phenomenon linked with the battery stack that causes battery deterioration is self-discharge. Here, this study involves the performance testing of a 19-cell VRFB for both lab- and pilot-scale electrolyte designs. Graphite bipolar plate sides were designed with additional extensions and three voltage measuring holes. Each electrolyte volume and flow rates were 4.0 and 250 L and 2.0 and 4.0 L min-1 for lab-scale and pilot-scale studies, respectively. Battery efficiencies are examined at various current density levels from 10 to 60 mA cm-2. Individual cell voltages are monitored to study the self-discharge of a VRFB. The study of battery stability and voltage distribution for individual cells leads to the conclusion that the potential difference at centrally located cells contributes significantly to battery self-discharge. This study is significant for an understanding of the limiting factors for developing VRFB-based grid energy storage. © 2022 American Chemical Society.