Repository logo
Institutional Digital Repository
Shreenivas Deshpande Library, IIT (BHU), Varanasi

Performance effect on the TEG system for waste heat recovery in automobiles using ZnO and SiO2 nanofluid coolants

dc.contributor.authorKarana, Dhruv Raj
dc.contributor.authorSahoo, Rashmi Rekha
dc.date.accessioned2020-01-20T07:26:53Z
dc.date.available2020-01-20T07:26:53Z
dc.date.issued2019-01
dc.descriptionHow to cite this article: Karana DR, Sahoo RR. Performance effect on the TEG system for waste heat recovery in automobiles using ZnO and SiO2 nanofluid coolants. Heat Transfer—Asian Res. 2019;48:216‐232. https://doi.org/10.1002/htj.21379en_US
dc.description.abstractEnhancement in heat transfer of the cold side is vital to amplify the performance of a thermoelectric generator (TEG). With enriched thermophysical properties of nanofluids, significant improvement in heat transfer process can be obtained. The current study concerns the performance comparison of an automobile waste heat recovery system with EG-water (EG-W) mixture, ZnO, and SiO2 nanofluid as coolants for the TEG system. The effects on performance parameters, that is, circuit voltage, conversion efficiency, and output power with exhaust inlet temperature, the total area of TEG, Reynolds number, and particle concentration of nanofluids for the TEG system have been investigated. A detailed performance analysis revealed an increase in voltage, power output, and conversion efficiency of the TEG system with SiO 2 nanofluid, followed by ZnO and EG-W coolants. The electric power and conversion efficiency for SiO 2 nanofluid at an exhaust inlet temperature of 500K were enhanced by 11.80% and 11.39% respectively, in comparison with EG-W coolants. Moreover, the model speculates that an optimal total area of TEGs exists for the maximum power output of the system. With SiO 2 nanofluid as a coolant, the total area of TEGs can be diminished by up to 34% as compared with EG-W, which brings significant convenience for the placement of TEGs and reduces the cost of the TEG system.en_US
dc.identifier.issn10992871
dc.identifier.urihttps://idr-sdlib.iitbhu.ac.in/handle/123456789/562
dc.language.isoen_USen_US
dc.publisherJohn Wiley and Sons Inc.en_US
dc.subjectCircuit voltageen_US
dc.subjectConversion efficiencyen_US
dc.subjectNanofluiden_US
dc.subjectReynolds numberen_US
dc.subjectThermoelectric generator (TEG)en_US
dc.subjectWaste heat recoveryen_US
dc.titlePerformance effect on the TEG system for waste heat recovery in automobiles using ZnO and SiO2 nanofluid coolantsen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Karana_et_al-2019-Heat_Transfer-Asian_Research.pdf
Size:
732.69 KB
Format:
Adobe Portable Document Format
Description:
Open Access Article

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: