Influence of Masonry Infill on Seismic Design Factors of Reinforced-Concrete Buildings

dc.contributor.authorShendkar, Mangeshkumar R.
dc.contributor.authorKontoni, Denise-Penelope N.
dc.contributor.authorIşik, Ercan
dc.contributor.authorMandal, Sasankasekhar
dc.contributor.authorMaiti, Pabitra Ranjan
dc.contributor.authorHarirchian, Ehsan
dc.date.accessioned2023-04-26T06:25:28Z
dc.date.available2023-04-26T06:25:28Z
dc.date.issued2022
dc.descriptionThis paper is submitted by the author of IIT (BHU), Varanasien_US
dc.description.abstractInfill walls are the most common separator panels in typical reinforced-concrete (RC) frame structures. It is crucial to investigate the influence of the infill walls on the earthquake behavior of RC frames. The load resistance of infill materials was often not taken into account in the designing phase, whereas the infill walls have significant contributions to the structural behavior under lateral and vertical loadings. A three-dimensional 4-story RC building is designed, and in order to make a realistic model, different infill walls configurations were taken into account with the openings in the infill. Four different models were created for structural analysis for infill wall effects, namely, full RC infilled frame (Model I), corner infill at ground story RC infilled frame (Model II), open ground story RC infilled frame (Model III), and bare RC frame (Model IV). Static adaptive pushover analysis has been performed for all structural models by using the SeismoStruct software. The double strut nonlinear cyclic model was used for modeling the infill walls. In this study, three different compressive strengths of infill walls are taken into consideration, and the effects on seismic design factors (namely, the response reduction factor, the ductility, the overstrength factor, and the deflection factor) are calculated. The obtained values of the response reduction factor (R) are compared with the given values in the BIS code. The results show that the R factors of all RC infilled frames are decreased when the compressive strength of the masonry infill reduces. However, the R values of bare frames are less than the corresponding values recommended in the BIS code. It is worth noting that the National Earthquake Hazards Reduction Program (NEHRP) provisions underestimate the deflection factors of the reinforced-concrete (RC) frames according to the evaluated deflection factors of the herein studied RC frames.en_US
dc.identifier.issn10709622
dc.identifier.urihttps://idr-sdlib.iitbhu.ac.in/handle/123456789/2296
dc.language.isoenen_US
dc.relation.ispartofseriesShock and Vibration;Article number 5521162
dc.subjectCompressive strengthen_US
dc.subjectConcrete buildingsen_US
dc.subjectEarthquakesen_US
dc.subjectInfill drillingen_US
dc.subjectSeismic designen_US
dc.subjectStructural analysisen_US
dc.subjectStructural framesen_US
dc.subjectWalls (structural partitions)en_US
dc.subjectFrame modelsen_US
dc.subjectInfill wallsen_US
dc.subjectInfilled frameen_US
dc.subjectMasonry infillsen_US
dc.subjectReduction factoren_US
dc.subjectReinforced concrete buildingsen_US
dc.subjectReinforced concrete frame structuresen_US
dc.subjectReinforced concrete framesen_US
dc.subjectResponse reductionsen_US
dc.subjectSeismic design factorsen_US
dc.subjectReinforced concreteen_US
dc.titleInfluence of Masonry Infill on Seismic Design Factors of Reinforced-Concrete Buildingsen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Influence-of-Masonry-Infill-on-Seismic-Design-Factors-of-ReinforcedConcrete-BuildingsShock-and-Vibration.pdf
Size:
2.84 MB
Format:
Adobe Portable Document Format
Description:
Article- Gold Open Access

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: