Transient Thermal Response of the Cathode Surface of a Potted Heater-Cathode Structure
| dc.contributor.author | Sil A.; Venkateswarlu D.S.; Chatterjee A.; Shukla M.M.; Rani A.J. | |
| dc.date.accessioned | 2025-05-24T09:55:17Z | |
| dc.description.abstract | This brief presents the experimental transient thermal profiles of the cathode surface of a practical potted heater cathode structure (standard 250 Spectra-Mat heater-cathode packaging). Temperature-time history has been obtained experimentally for various input heater power levels. The experimental results have been compared with the theoretical predictions earlier reported [3], and it has been found that in all the cases, the theoretical predictions are within 10% of the experimental results, thus validating the earlier reported theory. © 1994 IEEE. | |
| dc.identifier.doi | https://doi.org/10.1109/16.297750 | |
| dc.identifier.uri | http://172.23.0.11:4000/handle/123456789/19726 | |
| dc.relation.ispartofseries | IEEE Transactions on Electron Devices | |
| dc.title | Transient Thermal Response of the Cathode Surface of a Potted Heater-Cathode Structure |